Blood glucose and lipid Monitoring System

  • A convenient, accurate multi-functional monitoring system for total cholesterol, HDL, LDL, TG, and blood glucose levels

Additional information

Product Details:

 

INTRODUCTION

The importance of understanding lipid and glucose levels is paramount in reducing healthcare costs and deaths from preventable conditions1-3

Lipid monitoring is important because uncontrolled dyslipidemia can lead to the development of coronary heart disease.4

The National Cholesterol Education Program Adult Treatment Panel III (NCEP ATP III)
Total Cholesterol (mg/dL)
<200 Desirable
200-239 Borderline high
≥240 High

LDL Cholesterol (mg/dL)
<100 Optimal
100-129 Near optimal
130-159 Borderline high
160-189 High
≥190 Very high

HDL Cholesterol (mg/dL)
<40 Low
>60 High

Triglycerides (mg/dL)
<150 Desirable
150-199 Borderline high
200-499 High
≥500 Very high

 QR-201 Blood glucose and lipid Monitoring System employs two different forms of test methods: dry chemistry method & electrochemistry method

QR-201 provides a way for healthcare professionals to monitor lipids and glucose without the use of an outside laboratory or venipuncture 

 

STRENGTHS 

  • Large screen: 3 inch touch color screen, easy to operate
  • Fast and convenient: suitable for individuals, clinics and hospitals to quickly detect blood glucose and lipid
  • Fast result: accurate results can be shown in just 5 seconds
  • Data storage: blood glucose quality control data and detection data are stored separately
  • Gold test strips: with high precision and good repeatability
  • Long standby time: normally, it can be more than one month when fully charged

         

 

SPECIFICATIONS

Feature Description
1 Model Number QR-201
2 Test strips QR-11 blood glucose test strip, QR-21 blood lipid test card
3 Test Time GLU: 6 seconds, LIPID: 130 seconds
4 Measuring Range GLU: 1.1mmol/l~33.3mmol/l

Total Cholesterol: 2.59mmol/l~ 10.35mmol/l

Triglycerides: 0.51mmol/L~ 5.65mmol/L

HDL Cholesterol: 0.39mmol/L~ 2.59mmol/L

5 Sample whole blood, capillary blood
6 Sample size GLU: 0.8μL, LIPID: 40μL
7 Memory 1000 results
8 Coding coding
9 Calibration Automatically select test curve by the correcting code
10 Unit of measure mmol/L, or mg/dL
11 Average calculation 7-, 14- & 28-day results averaging
13 Battery ~220V,50Hz,0.35A
14 Battery life About 1000 tests
15 Automatic power off Approx. 2 minutes after last user action
15 Dimension 135mm×60mm×25mm (L x W x H)
17 Weight Handpiece: about 300g, charging base: 180g
18 Meter storage temperature -20℃~ 55℃ 10 ~ 93% RH
19 Warranty 2 years
Operating Ranges
1 Temperature 5℃~40℃, room temperature
2 Relative humidity 10 ~ 80% RH
3 Hematocrit 35%–55%
4 Altitude 3000 meters

 

REFERENCES 

  1. Third Report of the National Cholesterol Education Program (NCEP) Expert Panel on Detection, Evaluation, and Treatment of High Blood Cholesterol in Adults (Adult Treatment Panel III) final report. Circulation. 2002;106:3143-3421.
  2. CDC. 2014 National Diabetes Statistics Report. October 14, 2014. www.cdc.gov/diabetes/data/statistics/2014statisticsreport.html. Accessed July 20, 2014.
  3. CDC, Division for Heart Disease and Stroke Prevention. Cholesterol fact sheet. www.cdc.gov/dhdsp/data_statistics/fact_sheets/fs_cholesterol.htm. Accessed July 20, 2014.
  4. Mayo Clinic. High cholesterol. www.mayoclinic.org/diseases-conditions/high-blood-cholesterol/in-depth/triglycerides/art-20048186. Accessed June 10, 2014.